HZA

Generator sets Diesel from 3,80 to 40 kVA

HZA

Powered by HATZ
Industrial Range
 
50 Hz
Model R.P.M. P.R.P. Standby legislation / regulation
Model: HZA1-5C T5 R.P.M.: 1.500 P.R.P.: 4.7 Standby: 5.2 legislation / regulation: View model
Model: HZA3-10C T5 R.P.M.: 3.000 P.R.P.: 9.4 Standby: 10.4 legislation / regulation: View model
Model: HZA1-15C T5 R.P.M.: 1.500 P.R.P.: 14.4 Standby: 16.1 legislation / regulation: View model
Model: HZA1-25C T5 R.P.M.: 1.500 P.R.P.: 23 Standby: 25 legislation / regulation: Stage 3A View model
Model: HZA1-30C T5 R.P.M.: 1.500 P.R.P.: 30 Standby: 33 legislation / regulation: Stage 3A View model
Model: HZA1-20 T5 R.P.M.: 1.500 P.R.P.: 15.8 Standby: 17.5 legislation / regulation: View model
Model: HZA1-25 T5 R.P.M.: 1.500 P.R.P.: 25 Standby: 28 legislation / regulation: Stage 3A View model
Model: HZA1-35 T5 R.P.M.: 1.500 P.R.P.: 32 Standby: 35 legislation / regulation: Stage 3A View model
Model R.P.M. P.R.P. Standby legislation / regulation
Model: HZA1-4C M5 R.P.M.: 1.500 P.R.P.: 3.8 Standby: 4.2 legislation / regulation: View model
Model: HZA3-8C M5 R.P.M.: 3.000 P.R.P.: 7.4 Standby: 8.1 legislation / regulation: View model
Model: HZA1-15C M5 R.P.M.: 1.500 P.R.P.: 13.8 Standby: 14.9 legislation / regulation: View model
Model: HZA1-20C M5 R.P.M.: 1.500 P.R.P.: 19.2 Standby: 20 legislation / regulation: Stage 3A View model
Model: HZA1-20 M5 R.P.M.: 1.500 P.R.P.: 15.1 Standby: 16.2 legislation / regulation: View model
Model: HZA1-25 M5 R.P.M.: 1.500 P.R.P.: 23 Standby: 25 legislation / regulation: Stage 3A View model
Model: HZA1-35 M5 R.P.M.: 1.500 P.R.P.: 33 Standby: 36 legislation / regulation: Stage 3A View model
 
60 Hz
Model R.P.M. P.R.P. Standby legislation / regulation
Model: HZA1-6C T6 R.P.M.: 1.800 P.R.P.: 5.8 Standby: 6.3 legislation / regulation: TIER IV View model
Model: HZA1-20C T6 R.P.M.: 1.800 P.R.P.: 18.1 Standby: 20 legislation / regulation: INT. TIER IV View model
Model: HZA1-25C T6 R.P.M.: 1.800 P.R.P.: 28 Standby: 31 legislation / regulation: INT. TIER IV View model
Model: HZA1-35C T6 R.P.M.: 1.800 P.R.P.: 37 Standby: 41 legislation / regulation: INT. TIER IV View model
Model: HZA1-20 T6 R.P.M.: 1.800 P.R.P.: 19.7 Standby: 22 legislation / regulation: INT. TIER IV View model
Model: HZA1-30 T6 R.P.M.: 1.800 P.R.P.: 31 Standby: 35 legislation / regulation: INT. TIER IV View model
Model: HZA1-40 T6 R.P.M.: 1.800 P.R.P.: 40 Standby: 44 legislation / regulation: INT. TIER IV View model
Model R.P.M. P.R.P. Standby legislation / regulation
Model: HZA1-6C M6 R.P.M.: 1.800 P.R.P.: 4.6 Standby: 5.1 legislation / regulation: TIER IV View model
Model: HZA1-17C M6 R.P.M.: 1.800 P.R.P.: 17.4 Standby: 18.9 legislation / regulation: INT. TIER IV View model
Model: HZA1-20C M6 R.P.M.: 1.800 P.R.P.: 24 Standby: 25 legislation / regulation: INT. TIER IV View model
Model: HZA1-20 M6 R.P.M.: 1.800 P.R.P.: 19.2 Standby: 21 legislation / regulation: INT. TIER IV View model
Model: HZA1-30 M6 R.P.M.: 1.800 P.R.P.: 30 Standby: 32 legislation / regulation: INT. TIER IV View model
Model: HZA1-40 M6 R.P.M.: 1.800 P.R.P.: 40 Standby: 43 legislation / regulation: INT. TIER IV View model